Panasonic LinkRay 70" Class Full HD Commercial LED Display User Manual

Page 121

Advertising
background image

121

English

Symptoms

Check

[Controller ID function] function cannot be used.
(When using ID remote controller)

Check whether [Controller ID function] is set to [On], or <ID

MODE> switch is set to <ON>. (see page 74)
(When [Controller ID function] is set to [On], you need to set

<ID MODE> switch to <ON> and set the ID number.)

The top or bottom of the picture on the screen is cut

off.

The image position has been adjusted in the [Position]

menu.
Adjust the position of the picture on the screen.
(see page 38, 39)

There are areas at the top and bottom of the screen

where picture is not displayed.

When using a video software program (such as a cinema

size program) with a screen wider than one in the 16:9

mode, blank areas separate from the images are formed at

the top and bottom of the screen.

Parts of the unit become hot.

Even when the temperature of parts of the front, top and

rear panels has risen, these temperature rises will not pose

any problems in terms of performance or quality.

There is no picture displayed or sound output

sometimes.

When HDMI or DVI signals are input to the Display using a

selector or distributor, sound or images may not be output in

the normal fashion depending on the selector or distributor

used.
The symptoms may be improved by turning the power off

and on again, or by replacing the selector or distributor.

The RS-232C is uncontrollable.
(TH-65SF2U, TH-55SF2U, TH-49SF2U, TH-

43SF2U, TH-55SF2E, TH-49SF2E, TH-43SF2E)

Check whether the connection has been made properly.

(see page 23)

The RS-232C is uncontrollable.
(TH-65SF2E)

Check whether the connection has been made properly.

(see page 23)
To control RS-232C with the Display’s SERIAL IN terminal:
Check that [Network settings] - [Serial control] is set to

[SERIAL IN].
To control RS-232C with the twisted pair cable transmitter:
Check that [Network settings] - [Serial control] is set to

[DIGITAL LINK], [Network settings] - [Network control] is set

to [On] and [DIGITAL LINK mode] is set to [Auto], [DIGITAL

LINK] or [Long reach].
(see page 59, 60)

The LAN is uncontrollable.
(TH-65SF2U, TH-55SF2U, TH-49SF2U, TH-

43SF2U, TH-55SF2E, TH-49SF2E, TH-43SF2E)

Check that the connection has been made properly.
(see page 78)
To control with WEB browser control or command control,

check that [Network settings] - [Network control] is set to

[On].
(see page 59)
Check that [LAN setup] is set properly.
(see page 59)
When connecting to a device of AMX, Extron or Crestron

Electronics, Inc., set [AMX D. D.], [Extron XTP] or [Crestron

Connected™] according to the device to use.
(see page 61)