Daisy chain connection

It is possible to daisy chain multiple displays when

displaying the picture on multi screen, etc.

DIGITAL LINK

First display
Second display
Third display

Note

It is possible to daisy chain up to 10 displays.

However, the number of connectable displays may be

limited depending on the cables, signals, the devices

used, etc.

When inputting HDCP signal, it is possible to daisy

chain up to 8 displays.

The DVI-D output function is enabled only for the

DVI-D input.
This is not output if the HDMI or DIGITAL LINK input

is selected. When using the daisy-chain connection

method, all the displays should be in the state where

the picture is displayed via DVI-D IN.

Pin assignments and signal names for DVI-D

Input/Output

Pin No.

Signal Name

T.M.D.S. data 2-
T.M.D.S. data 2+
T.M.D.S. data 2 shield

DDC clock
DDC data

T.M.D.S. data 1-
T.M.D.S. data 1+
T.M.D.S. data 1 shield

+5 V DC
GND (Ground)
Hot plug detect
T.M.D.S. data 0-
T.M.D.S. data 0+
T.M.D.S. data 0 shield

T.M.D.S. clock shield
T.M.D.S. clock+
T.M.D.S. clock-