[Gateway]:

(Gateway address display and setting)

Enter a gateway address when DHCP server is not

used.

Note

When [DHCP] is set to [On], the IP address, etc. will

be displayed in grey.

Entering numbers

I

1

92.168.000.008

IP address

1. Select the address and press <ENTER>.
2. Select digits with .
3. Change numbers with .
4. Press <ENTER>.

You can cancel the change by pressing

<RETURN>.

Select [Save] and press <ENTER>.

Save the current network Setup.

Note

To use a DHCP server, make sure the DHCP

server is started.

Contact your network administrator for details on

[IP address], [Subnet mask] and [Gateway].

Shipping condition
[DHCP]: Off
[IP address]: 192.168.0.8
[Subnet mask]: 255.255.255.0
[Gateway]: 192.168.0.1

[Port]

Set the port number used for command control.

Select [Port] and press <ENTER> to set the number.

The available setting range is 1024 ‒ 65535.

Entering numbers (see page 60)

Note

When the PJLink protocol is used, the port setting is

not necessary.

[MAC address]

Displays the MAC address of this unit.

[Network status]

Checks the current Network settings status.

192. 168. 0. 1

255. 255. 255. 0

192. 168. 0. 8

12:34:56:78:9A:BC

Network status

DHCP
IP address
Subnet mask
Gateway
MAC address

Off

[DIGITAL LINK mode]
(TH-65SF2E only)

Switches communication method of DIGITAL LINK

terminal.

[Auto]:

Communication method is selected automatically.
HDMI, LAN, serial communication are possible.
Ethernet connection is possible.

[DIGITAL LINK]:

HDMI, LAN, serial communication are possible via a

twisted pair cable transmitter.

[Ethernet]:

LAN communication is possible via the LAN terminal

of the display.

[Long reach]:

Communication method is fixed to Long reach.

Modes allowing communication

:

Valid

― :

Invalid

Settings

Communication validity

Picture

transmission Ethernet RS-

232C

100 m 150 m

Auto

For

DIGITAL

LINK

For Long

reach

For

Ethernet

DIGITAL LINK

Long reach

Ethernet

Note

When connected with the [Long reach]

communication method, the maximum

transmission distance is 150 m. In this case, this

unit can receive the signals of up to 1080/60p

(148.5 MHz).

If the communication method of the twisted

pair cable transmitter is set to [Long reach], set

[DIGITAL LINK mode] to [Auto]. Then, connection

is enabled with the [Long reach] communication

method.
When connecting with the separately sold DIGITAL

LINK Switcher (ET-YFB200G) with the [Long

reach] communication method, set [DIGITAL LINK

mode] to [Long reach].

Even if [DIGITAL LINK mode] is set to [Long

reach], when the twisted pair cable transmitter

does not support the communication method of

[Long reach], it will not be connected properly.