When [lan control protocol] is set to [protocol 2 – Panasonic LinkRay 70" Class Full HD Commercial LED Display User Manual

Page 82

Advertising
background image

English

82

2. When [LAN control protocol] is set

to [Protocol 2].

Communicates with the same protocol as that of a

Panasonic projector

When the WEB control administrator

privileges password has been set (Protect

mode)

Connection method

1

Obtain the display’s IP address and the port number

(Default is 1024), and request connection to the

display.
The IP address and the port number can be obtained

from the following menus.

IP address:
[Setup

] → [

Network settings

] → [

LAN setup] or

[Network status]

Port number:
[Setup

] → [

Network settings

] → [

LAN setup]

For more detail of the settings, see page 59.

2

The display responds.

Response data

Data part Space Mode Space

Random

number

part

Last

terminal

symbol

[NTCONTROL]

(ASCII

character

string)

[ ]

0x20

[1]

0x31

[ ]

0x20

[zzzzzzzz]

(ASCII

code

hex

number)

(CR)

0x0d

9 bytes

1 byte 1 byte 1 byte 8 bytes 1 byte

Mode: 1 = Protect mode

3

Hash the following data with the MD5 algorithm, and

generate a 32-byte hash value.

[xxxxxx:yyyyy:zzzzzzzz]

xxxxxx :
WEB control administrator privileges user name
yyyyy :
Above administrator privileges user password

Default user name and password are as

follows:
User name: dispadmin
Password: @Panasonic

zzzzzzzz :
8-byte random number obtained in step 2

Command transmission method

Transmit in the following command format
Transmitted data

Header

Data part

Last

terminal

symbol

Hash value

(see

“Connection

method”)

‘0’

0x30

‘0’

0x30

Control

command

(ASCII

character

string)

(CR)

0x0d

32 bytes

1 byte

1 byte Undefined 1 byte

Received data

Header

Data part

Last

terminal

symbol

‘0’

0x30

‘0’

0x30

Control

command

(ASCII

character

string)

(CR)

0x0d

1 byte

1 byte

Undefined

1 byte

Error response

Error message

Last

terminal

symbol

“ERR1”

: Undefined control

command

(CR)

0x0d

“ERR2”

: Out of parameter range

“ERR3”

: Busy status or

reception invalid period

“ERR4”

: Timeout or reception

invalid period

“ERR5”

: Wrong data length

“ERRA”

: Mismatching of

password

4 bytes

1 byte

Advertising