Pin assignments and signal names for SERIAL

Terminal

6

7

8

9

1

3 4

5

2

Pin No.

Signal Name

NC (not connected)
RXD
TXD
Non use
GND (Ground)
Non use
RTS

Shorted in this set

CTS
NC (not connected)

These signal names are those of computer

specifications.

Communication parameters

Signal level: RS-232C compliant
Synchronization method: Asynchronous
Baud rate: 9600 bps
Parity: None
Character length: 8 bits
Stop bit: 1 bit
Flow control: None

Basic format for control data

The transmission of control data from the computer

starts with a STX signal, followed by the command, the

parameters, and lastly an ETX signal in that order. If

there are no parameters, then the parameter signal does

not need to be sent.

STX C1 C2 C3

P1 P2 P3 P4

:

P5

ETX

Start

(02h)

3-character command

(3 bytes)

Colon

Parameter(s)

End

(03h)

Command

Command

Parameter

Control details

PON

None

Power ON

POF

None

Power OFF

AVL

***

Volume 000 ‒ 100

AMT

0

Audio MUTE OFF

1

Audio MUTE ON

IMS

None

Input select (toggle)

HM1

HDMI 1 input

(HDMI1)

HM2

HDMI 2 input

(HDMI2)

DL1

DIGITAL LINK input
(DIGITAL LINK)

DV1

DVI-D IN input

(DVI-D)

PC1

PC IN input (PC)

VD1

AV IN input (VIDEO)

UD1

USB input (USB)

MV1

“Memory viewer”

input
(MEMORY VIEWER)

DAM

None

Screen mode select

(toggle)

ZOOM

Zoom1

FULL

16:9

NORM

4:3

ZOM2

Zoom2

Note

If multiple commands are transmitted, be sure to wait

for the response for the first command to come from

this unit before sending the next command.

If an incorrect command is sent by mistake, this

unit will send an “ER401” command back to the

computer.

When sending a command which does not require

parameter, a colon (:) is not needed.

Consult your local Panasonic dealer for detail

instructions on command usage.