Back-to-back configuration – Interphase Tech iSPAN User Manual

Page 52

Advertising
background image

Back-to-Back Configuration

32

Interphase Corporation

Back-to-Back Configuration

The iSPAN-Serial WAN adapter can be connected to another
serial adapter in a back-to-back configuration.

If the other adapter is also an iSPAN-Serial, the preferred
interface is V.11; the cable must have the wiring shown in the
following illustration. Both adapters must provide clocks.

Following is an illustration of a back-to-back cable
configuration.

Figure 3-7. Back-to-Back Cable Wiring

Adapter

side

DCE
side

Male DB25

connector

Male DB25

connector

Drain wire

Braid

3

16

2

14

17

9

24

11

5

13

4

19

7

18

1

2

14

3

16

24

11

17

9

4

19

5

13

7

18

1