Bx.25 timer settings, Bx.25 timer settings -8 – Kentrox AI296 User Manual

Page 102

Advertising
background image

AI296 Version 9.8x User’s Guide

Link Configuration: BX.25 Configuration

6-8

Configuration in the AI296 Local Menu System

1. Access the X.25 Link Menu.

2. Select

BX.25 Menu

. The BX.25 Menu appears.

3. For

BX.25 Support

, select

Enabled

or

Disabled

. The default is

Disabled

.

This example displays

BX.25 Support

set to

Enabled

.

BX.25 Timer Settings

Description

The initial BX.25 timer settings are configured using two menu items:

z

Connect timer ST2

—Defines the maximum number of seconds that the BX.25

protocol will wait for a response to a session connect request.

z

Send timer ST3

—Defines the data acknowledge timer, which gives the maximum

number of seconds that the BX.25 protocol will wait for an acknowledgement to a
Data Request.

Menu Item Type

Data

Link Type Availability

X.25

Configuration in the AI198 Menu System

1. Access Menu 4.2.11.12.11.

2. For

05 Connect Timer ST2

, enter

5,

and the connect timer value. Valid values are

0

to

65535

. The default is

12

.

3. For

06 Send Timer ST3

, enter

6,

and the send timer value. Valid values are

0

to

65535

. The default is

18

.

BX.25 Menu

Link being configured . . . . . . . . . . . . . . . . . . . . . . . . . 03

BX.25 Support . . . . . . . . . . . . . . . . . . . . [Enabled] Disabled