General link properties are configurable using menus accessed directly from the link
configuration menu. The following configuration items are available:

Auto Disable Error Limit

Description

This menu item disables a link when the rate of errors received on that link exceeds a
user-specified threshold. This prevents a bad link or cable from streaming enough
errors to lock up or crash AI296.

Menu Item Type

Data

Link Type Availability

Async, AsyncPPP, HDLC-Bridge, MLT, SyncPPP, and X.25

Configuration in the AI198 Menu System

1. Access Menu 4.2.11.12.

2. For

Auto Disable Error Limit

, enter the associated item number, a comma, and the

error limit value. (For example,

9,25000

.) The default is

0

.

z

Auto Disable Error Limit

z

Link Type

z

Flow Control

z

Passive Link with Clocking

z

Hardware Interface (Interface Type)

z

Port Data Bits

z

Interface Mode

z

Port Parity

z

Link Description

z

Port Speed

z

Link Mode

z

Port Stop Bits

z

Link Number

z

Sync Port Encoding

z

Link State

z

Xon Repeat Interval

Advertising