X.25 counter settings, X.25 counter settings -78 – Kentrox AI296 User Manual

Page 172

Advertising
background image

AI296 Version 9.8x User’s Guide

Link Configuration: X.25 Parameters Configuration

6-78

Configuration in the AI296 Local Menu System

1. Access the X.25 Link Menu.

2. Select

X.25 Parameters Menu

. The X.25 Parameters Menu appears.

3. For

Protocol Version

, select

1980

,

1984

, or

1988

. The default is

1984

.

This example displays

Protocol Version

set to

1988

.

X.25 Counter Settings

Description

The X.25 counter settings are configured using four menu items:

z

R20 restart counter

—Defines the maximum number of times a reset can be sent

without receiving reset confirmation.

z

R22 reset transmission counter

—Defines the maximum number of times a reset

can be sent without receiving clear confirmation.

z

R23 clear transmission counter

—Defines the maximum number of times a clear

request can be sent without clearing confirmation.

z

R28 registration transmission counter

—Defines the maximum number of times a

registration request can be sent without receiving registration confirmation.

Menu Item Type

Data

X.25 Parameters Menu

Link being configured . . . . . . . . . . . . . . . . . . . . . . . . . 03

X25 Facilities Negotiation . . . . . . . . . . . . . Enabled [Disabled]
Max Packet Size . . . . . . . . . . . . . . . . . . . . [128] 256 512
Packet Window Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
X121 Local Address . . . . . . . . . . . . . . . . . . . . . ................
T20 Restart Timer . . . . . . . . . . . . . . . . . . . . . . . . . . .1750000
T21 Call Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . .1000000
T22 Reset Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 20000
T23 Clear Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . 180000
T24 Window Timer . . . . . . . . . . . . . . . . . . . . . . . . . . .2356000
T25 Data Retransmission Timer . . . . . . . . . . . . . . . . . . . . .1650000
T26 Interrupt Timer . . . . . . . . . . . . . . . . . . . . . . . . . .2300000
T28 Registration Timer . . . . . . . . . . . . . . . . . . . . . . . .. 90000
R20 Restart Counter . . . . . . . . . . . . . . . . . . . . . . . . . . . .150
R22 Reset Transmission Counter . . . . . . . . . . . . . . . . . . . . . . 25
R23 Clear Transmission Counter . . . . . . . . . . . . . . . . . . . . . . 34
R28 Registration Transmission Counter . . . . . . . . . . . . . . . . . . . 52
Protocol Version . . . . . . . . . . . . . . . . . 1980 1984 [1988]

Advertising