Kentrox AI296 User Manual

Page 271

Advertising
background image

AI296 Version 9.8x User’s Guide

AI296 Commands: alarm

9-13

Examples

This example displays a list of the alarm groups and the overall alarm severity.

-clear

Clears all non-self-clearing alarm groups or a specified non-self-clearing
alarm group.



Note: Only non-self-clearing alarm groups can be manually cleared.

Self-clearing alarms clear themselves when the problem that
caused the alarm is resolved.

The following parameter is accepted:

group

—Defines the group of alarms to display, clear, mask, or

unmask. Valid values are existing alarm groups.

-mask

Prevents a specified alarm group from affecting overall alarm severity.
The following parameter is accepted:

group

—Defines the group of alarms to display, clear, mask, or

unmask. Valid values are existing alarm groups.

-unmask

Allows a specified alarm group to affect overall alarm severity. The
following parameter is accepted:

group

—Defines the group of alarms to display, clear, mask, or

unmask. Valid values are existing alarm groups.

[296]alarm
Alarm Group Sev Date & Time Message (most recent, most severe in group)
----------- --- ----------- ----------------------------------------------
*general 0 00-00 00:00
links 0 06-01 00:00 Link 1 up.
----------- --- ----------- ----------------------------------------------
*not self-clearing () masked
Overall alarm severity: 0
[296]