AI296 Version 9.8x User’s Guide

Link Configuration: Virtual Circuit Configuration

6-88

2. Enter a value (

02

through

15

) associated with the PVC to be configured. Menu

4.2.11.12.9.2.1 (the PVC Edit Menu) appears.

3. For

01*PVC Type

, enter

1

to select

Passive

,

Active

, or

Connect on activity

. The default

is

Passive

.

4. For

02 LCN Low

, enter

2,

and the minimum LCN value. Valid values are

1

to

1024

.

The default is

1

.



Note: An asterisk (

*

) configures all LCNs for the link with values defined in menu

item 4.2.1114.12.9.1.

5. For

03 LCN High

, enter

3,

and the maximum LCN value. Valid values are

1

to

1024

.

The default is

1

.

6. For

04 RESET Timer Interval

, enter

4,

and the reset timer interval value.

The timer type, range, and default settings depend on the PVC type. Refer to

Table 6-1

for PVC types, timer types, ranges, and defaults.

>3
Menu 4.2.11.12.9.2.1
01*PVC Type (Passive, Active, Connect on activity)----------------------Passive
02 LCN Low (* for all LCNs for the link)-----------------------------------0001
03 LCN High----------------------------------------------------------------0001
04 RESET Timer Interval (seconds)-----------------------------------------00000

20 Save the changes made
21 Exit this menu with no changes
Enter item number and optional ",value" then push <CR> key
>

Table 6-1 PVC and Timer Type

PVC Type

Timer Type

Range

Default

Active

Call Timer

30 to 600 s

30 s

Connect on Activity

Inactivity Timer

1 to 600 s

1 s