Syncflash, Syncflash -94 – Kentrox AI296 User Manual

Page 352

Advertising
background image

AI296 Version 9.8x User’s Guide

AI296 Commands: syncflash

9-94

syncflash



Note: This command is only available when AI296 is in standalone mode.

Description

This command synchronizes the AI296 configuration with the configuration
information stored on AI198. Enabling this feature ensures that if AI296 is placed in
standalone mode, it will operate as it did in switch mode.

Command Type

shell

Formats

syncflash {

true

|

false

}

Parameters



Note: When running in standalone mode, AI296 always writes to its file system when

configuration changes are made. When running in switch mode, the running
configuration on AI296 is always kept current with AI198's configuration.

Examples

This example displays the AI296 configuration being synchronized with the
configuration information stored on AI198.

true

Enables the update configuration functionality.

false

Disables the update configuration functionality.

[296]syncflash true
[296]