AI296 Version 9.8x User’s Guide

Link Configuration: LAPB Parameters Configuration

6-49

Menu Item Type

Toggle

Link Type Availability

MLT and X.25

Configuration in the AI198 Menu System

1. Access menu 4.2.11.12.7 for MLT or menu 4.2.11.12.8 for X.25.

2. For

01*Interface mode

, enter

1

to select

DCE

or

DTE

. The default is

DCE

.

This example displays

01*Interface mode

set to

DTE

.

LAPB Timer Settings

Description

The LAPB timer settings are configured using three menu items:

z

T1 ack timer

—Defines the maximum amount of time from the end of transmission

to the receipt of an acknowledgment.

z

T2 ack delay timer

—Defines the time available from the receipt of a frame until a

response has to be transmitted.

z

T4 idle timer

—Defines the maximum time allowed without the exchange of

frames on a data link.

Menu Item Type

Data

Link Type Availability

MLT and X.25

Configuration in the AI198 Menu System

1. Access menu 4.2.11.12.7 for MLT or menu 4.2.11.12.8 for X.25.

2. For

05 T1 ack timer

, enter

5,

and the timer value. The default is

3000

.

3. For

06 T2 ack delay timer

, enter

6,

and the timer value. The default is

4000

.

4. For

07 T4 idle timer

, enter

7,

and the timer value. The default is

25000

.

>1
Menu 4.2.11.12.8
01*Interface mode (DTE or DCE)----------------------------------------------DTE