AI296 Version 9.8x User’s Guide

Link Configuration: RTS/DTR Lead Control Configuration

6-73

RTS disconnect state

—Sets the RTS disconnect state to one of the following options:

z

On

—Sets RTS to on when the link disconnects.

z

Off

—Sets RTS to off when the link disconnects.

z

Toggle

—Makes RTS pulse when the link disconnects. The pulse polarity is

opposite to the sense specified for the connected state.

Menu Item Type

Toggle

Link Type Availability

Async and AsyncPPP and SyncPPP

Configuration in the AI198 Menu System

1. For an asynchronous or asynchronous PPP link, access menu 4.2.11.12.13.

2. For

03*RTS connect state

, enter

3

to select

ON

,

OFF

, or

FLOW CONTROL

. The default is

ON

.

3. For

04*RTS disconnect state

, enter

4

to select

ON

,

OFF

, or

TOGGLE

. The default is

OFF

.

This example displays

03*RTS connect state

set to

FLOW CONTROL

and

04*RTS disconnect

state

set to

TOGGLE

.

Configuration in the AI296 Local Menu System

1. Access the Async Link Menu or AsyncPPP Link Menu.

2. Select

RTS/DTR Lead Control Options Menu

. The RTS/DTR Lead Control Options

Menu appears.

3. For

RTS connect state

, select

On

,

Off

, or

FlowControl

. The default is

On

.

4. For

RTS disconnect state

, select

On

,

Off

, or

Toggle

. The default is

Off

.

>4
Menu 4.2.11.12.13
01*DTR connect state---------------------------------------------------------ON
02*DTR disconnect state (On, Off, Toggle)-----------------------------------OFF
03*RTS connect state (On, Off, Flow Control)-----------------------FLOW CONTROL
04*RTS disconnect state (On, Off, Toggle)--------------------------------TOGGLE