AI296 Version 9.8x User’s Guide

Link Configuration: Disconnect Options Configuration

6-21

This example displays

Disconnect when DCD is off

set to

On

and

Disconnect when a Break

character is received

set to

Off

for an async link.

Disconnect String

Description

This menu item configures the string the link sends before the link disconnects. The
following character values apply:

z

<b>

sends a break signal.

z

<

n

>

represents the decimal value of an ASCII character. Valid values are 0 to 255.

z

text

represents the text value in the string.

z

<p

#

>

represents a pause control sequence.

#

is the number of tenths of seconds

to pause. Valid values are 1 to 20 (for 0.1 seconds to 2 seconds).

For example, string

<b>login<13><p 10><b>

sends:

z

A break signal

z

The text “login”

z

A carriage return

z

A one second pause

z

Another break signal.

Menu Item Type

Data

Link Type Availability

Async

Configuration in the AI198 Menu System

1. Access Menu 4.2.11.12.12.

2. For

07 Disconnect string

, enter

7,

and the disconnect string. Maximum length is

80 characters.

Disconnect Options Menu

Link being configured . . . . . . . . . . . . . . . . . . . . . . . . . 4

Disconnect when DCD is off . . . . . . . . . . . . . . . . . . . [On] Off
Disconnect when a Break character is received . . . . . . . . . On [Off]