Pvcedit, Pvcedit -78 – Kentrox AI296 User Manual

Page 336

Advertising
background image

AI296 Version 9.8x User’s Guide

AI296 Commands: pvcedit

9-78

pvcedit

Description

This command allows a change to occur on a PVC without bringing down (bouncing)
the entire link. This command can also be used to reset the PVC without resetting the
entire link. If no options are specified, the PVC is simply reset. This command also
has the following constraints:

z

Only asynchronous and X.25 PVCs are to be used.

z

Asynchronous PVCs can be reset only.

z

X.25 PVCs can be reset and altered.

Command Types

shell and winslc

Formats

For the AI296 system command:

pvcedit

asy.

link_number

.

lcn

[ -a

call_timer

| -c

inactivity_timer

| -p ]

x25.

link_number

.

lcn

[ -a

call_timer

| -c

inactivity_timer

| -p ]

For the winslc command:

winslc

baseport

pvcedit

asy.

link_number

.

lcn

[ -a

call_timer

| -c

inactivity_timer

| -p ]

x25.

link_number

.

lcn

[ -a

call_timer

| -c

inactivity_timer

| -p ]

Parameters

-a

Forces the PVC to activate with the corresponding call
timer.

asy.

link_number

.

lcn

Defines the link number and logical channel number for
the asynchronous PVC being edited.

baseport

Defines the baseport number for AI296.

-c

Forces the PVC to connect on activity with the
corresponding inactivity timer.

call_timer

Defines the value of the call timer. Valid values are from
30 to 600.

inactivity_timer

Defines the value for the inactivity timer. Valid values are
from 1 to 600.

Advertising