Link Configuration: Virtual Circuit Configuration

6-85

Virtual Circuit Configuration

The following settings are available for X.25 parameter configuration:

z

Number of PVCs

z

PVC Configuration Settings

z

SVC Configuration Settings

Number of PVCs

Description

This menu defines the number of PVCs being configured. A PVC is a virtual circuit
that is permanently available. PVCs differ from SVCs in that an SVC must be
reestablished each time data is to be sent. Once the data has been sent, the SVC
disappears. PVCs are more efficient for connections between hosts that communicate
frequently.

Menu Item Type

Data

Link Type Availability

X.25

Configuration in the AI198 Menu System

1. Access Menu 4.2.11.12.9.

2. For

01 Number of PVCs

, enter

1,

and the number of PVCs. The default is

0

.

This example displays

01 Number of PVCs

set to

15

.

Configuration in the AI296 Local Menu System

1. Access the X.25 Link Menu.

2. Select

Quick X.25 Menu

. The Quick X.25 Menu appears.

3. For

Number of PVCs

, enter the number of PVCs . The default is

0

.

>1,15
Menu 4.2.11.12.9
01 Number of PVCs (0 - 1024)-----------------------------------------------0015