AI296 Version 9.8x User’s Guide

Link Configuration: Virtual Circuit Configuration

6-91

Menu Item Type

Data

Link Type Availability

X.25

Configuration in the AI198 Menu System

1. Access Menu 4.2.11.12.9.

2. For

03 Incoming only SVC low

, enter

3,

and the minimum LCN used for incoming

only SVCs. The default is

0

.

3. For

04 Incoming only SVC high

, enter

4,

and the maximum LCN used for incoming

only SVCs. The default is

0

.

Important: AI296 can only receive calls on incoming only SVCs that are greater

than the maximum PVC.

4. For

05 Two-way SVC low

, enter

5,

and the minimum LCN used for an SVC. The

default is

1

.

Important: This value must be greater than the number of PVCs and/or

incoming SVCs.

5. For

06 Two-way SVC high

, enter

6,

and the maximum LCN used for an SVC. The

default is

1

.

6. For

07 Outgoing only SVC low

, enter

7,

and the minimum LCN used for outgoing

only SVCs. The default is

0

.

7. For

08 Outgoing only SVC high

, enter

8,

and the maximum LCN used for outgoing

only SVCs. The default is

0

.

Important: AI296 can place calls on outgoing only SVCs greater than the

maximum PVC and/or two-way SVC.