j)
Motor-S:
Remove the Motor-S by removing the
connector of motor and the two screws
1.
(2)
Reassembly procedure
Reverse the disassembly procedures.
k)
Photo-Sensor (PC1, PC2):
After disconnecting the two connectors,
remove the photo-coupler sensors PC1
and PC2 on the Plate Scanner B by press-
ing the latch using the flat screwdriver or
like.
Screw 1
Motor-S
Connector
(CP4.1 Fig. 19)
(CP4.1 Fig. 20)
PC2
PC1
Plate Scanner B