40055101TH Rev.4

609 /

2

1

3

8

9

C

B

A

0

6

7

4 Hopping Roller Shaft Assy

5

3.3.2

TQSB2-PCB

(1)

Remove the pulse motor (see 3.3.1).

(2)

Remove the connector O from the TQSB-2PCB P.

(3)

Remove the screw Q and remove the TQSB-2PCB P.

Note :

Refer to Detall A in the previous page.

3.3.3

Hopping Roller Shaft Assy and One-way Clutch Gear

(1)

Follow up to step (3) of 3.3.1 and remove the hopping frame assy.

(2)

Remove the screw 1 and remove the earth plate 2. Remove the sensor lever 7

and remove the ground

plate 6. Remove the gear 3 and remove the metal bush 5 and Hopping Roller shaft Assy 4.

(3)

Remove the E-ring A and remove the one-way clutch gear B on the right side of the feed roller 0.

Note :

The metal bush C also comes off. Be careful not to lose it.