7.2.16 No Acoustic Line Monitor

There are two source routes of acoustic line monitor:

(a)

General communication signal

(b)

DP pulse signal

Start

No

MONITOR CONTROL

(Technical function No. 02)

has been set to OFF?

Replace MCNT Board.

The signal appears?

Replace the speaker.

Connect oscilloscope probe

across CN8-01 (SP) and

CN8-02 (AG).

MONITOR VOLUME

(Function program No. 06)

has been set to

LOW or HIGH?

Set MONITOR VOLUME

to LOW or HIGH.

No (ON)

Yes

Yes

Yes (OFF)

Set it to ON.

A message can be

received normally?

Go to 7.2.9.

(Reception problem)

No

Yes

Signal route:
CN6-A6, B6 (R)

IC12-1 (RM)

TR1-2

IC11-3

IC5-5

No