1.

Block diagram

The circuit diagram shown on page 5/12 consists of the following functions:

IC6 (A/D converter)

30 V/24 V conversion circuit

Connector CN5 that provides an interface between R44 board and CIS (contact image sensor).

Figure A3.1.5 shows the related signals and block diagram of CIS.

2.

Function

One-line picture data is read in the sequence from the scanning unit (CIS) as SIG signal (analog

data) to A/D converter (analog/digital converter) of IC6. After conversion from analog data to 6-
bit digital signal (SDATA0 - SDATA5) under the control of IC6, this picture data is sent to
IOGA3 (input/output gate array). Here, the picture data undergoes various kinds of picture
processings.

Sensor interface signal output from IOGA3

LEDON :

LED on/off control signal

SNSCLK :

Scanning sensor drive clock (714.286 kHz)

MISP

:

Scanning synchronous signal (5 msec)

ADCLK :

Sampling clock for A/D converter (714.286 kHz)

A3.1.6

R44 Circuit Diagram (Page 6/12)

Shift register & analog switches

CN5

10

3

4

2, 5, 7

-8 V

0 VA

CIS (contact image sensor)

R44

VLED

+5 V

-8 V

0 VA

LEDs array

Rod lens array

sensor

1728 bit (216 mm)

+5 V

9

6

8

1

VLED (+24V)

GLED

MISP

DCK

SIG

GLED

MISP

DCK (714.286 kHz)

SIG

A/D converter

Amplifier

TR9/TR10

Transistor

LEDON

IOGA

IC2

SDATA0 - SDATA5

IC6

30 V/24 V conversion
circuit

30V

24 V

Figure A3.1.5 Related Signals and Block Diagram of CIS (contact image sensor)