Oki B4100 User Manual

Page 201

Advertising
background image

40055101TH Rev.4

201 /

Ground Terminal

LC2-3 Pin

Crystal Oscillator

Connector CN5-1 pin (SIG)

Ground Terminal

Connector CN7

CN7-1, 2, 3 (+5VDC)
CN7-8 (+30VDC)
CN7-9 (–8VDC)
CN7-12 (+5VSUB)

5.2.2 OKIOFFICE44/OKIFAX 4100 Measurement

1)

Remove the AC power cord.

2)

Carry out the disassembly procedure up to Cover assembly-top, Frame assembly-scanner, and Unit-
printer.
(Refer to the Mechanical Disassembly and Reassembly in Chapter 4-1.)

3)

Connect extension cables to the R44 board.

4)

Connect the frequency counter (for clock frequency), digital voltmeter (for power voltage) and
Oscilloscope (for SIG signal). See figure 5.2.1.

5)

Reconnect the AC power code.
Main power supply is set to "ON" (PC1 ON) by loading the document on the cover-top.
(except +5V SUB)

6)

Measurement

7)

Remove the AC power code.

8)

Reverse the disassembly procedures.

Figure 5.2.1 Measurement Points on R44 Board