3)

High-voltage and medium-voltage control

High voltages are activated by IOGA3 and generated by the high-voltage circuit inside the
power supply unit. The CH (charge) voltage of about -1.35 kV is used for the charge roller.
The TR1/TR2 (transfer) voltage of about +3.5 kV/-0.75 kV is used for the transfer roller.

Medium voltages are activated by IOGA3 and generated by the medium-voltage circuit
inside the power supply unit. The SB1/SB2 (toner supply) voltage of about +0 V/-450 V is
used for the toner supply roller. The DB1/DB2 (developping) voltage of about +300 V/-
300 V is used for the developing roller. The CB (cleaning) voltage of about +400V is used
for the cleaning roller.

Figure A3.2.19 shows high/medium voltages control.

* Signals used to control the high/medium-voltages are listed below.

Signal Name

CHPWM

P.W.M : CH is output.

Description

DB1ENB

"1": + ive polarity voltage of DB1/SB1 is output.

DB2ENB

"1": - ive polarity voltage of DB2/SB2/CB is output.

TR1PWM

P.W.M : TR1 is output.

TR2PWM

P.W.M : TR2 is output.

DBPWM

P.W.M : DB/SB/CB is output.

IOGA3

DBON1
DBON2
DBPWM
TR1PWM
CHPWM
TR2PWM

M17

1VP/2VP (Power supply unit)

High-voltage
generation
circuit

Medium-
voltage
generation
circuit

Contact assy.

Cleaning roller

Charge roller

EP drum

Transfer roller

Developing roller

Toner supply roller

CH

TR1/TR2

CB

DB1/DB2

SB1/SB2

Figure A3.2.19 High/Medium Voltage Control