Figure a3.1.16 fuser unit temperature control – Oki B4100 User Manual

Page 401

Advertising
background image

40055101TH Rev.4

401 /

The heater in the fuser unit is controlled by the thermister, IOGA and CPU to keep the
heater roller surface within a prescribed temperature range. The CPU supervises the status
of PC0 (A/D converter input section) periodically, turning HEATON- N signal on and off
according to CPU of PC0 status to exercise temperature control.
At power on time, the CPU switches the output signal THON from pin 65 (between high
and low states) to check for a blown or shorted thermister according to the status of the
THCHK signal.
A built-in thermostat in the fuser unit prevents the heater from being overheated in event of
failures in the thermister, or temperature control circuit, etc.

Figure A3.1.16 shows the fuser unit temperature control.

Note: Heater control

Temperature of the heater at the time of printing is 150 ˚C to 180 ˚C. This tempera-
ture is maintained by controlling the on and off operation of heater according to the
input of the thermister converted into analogue-digital (A/D) values by the CPU.

2)-1

Heater control

The ACON control signal on the secondary side is transmitted to the primary side via PC3
to turn triac TRC1ON for AC voltage supply to the heater.

3)

High-voltage and medium-voltage control

Figure A3.1.16 Fuser Unit Temperature Control

CPU

Heater

on/off circuit

IOGA

HEAT-N

R44

0V

0V

ACIN

F1

THCHK

5V

TRC1

AOUT

PC3

048-POW

Thermostat

Thermistor

Heater

Fuser unit

PC0

PA11

OLHV/TLHV

Board

THCHK

THON

+5V

ACON

CN7

10

CN6

13

IC2

HEATON

Advertising