Oki B4100 User Manual

Page 410

Advertising
background image

40055101TH Rev.4

410 /

A3.2.8

M17 Circuit Diagram (Page 9/17)

1.

Block diagram

The circuit diagram shown on page 9/17 consists of the following connectors:

Connector CN6 that provides an interface between M17 board and NCU board.

Connector CN7 that provides an interface between M17 board and external electro-mechanical
devices (PC1 and PC2).

Connector CN9 that provides an interface between M17 board and OPE (O5W) unit.

Figure A3.2.9 shows an interface between M17 board and NCU board.
Figure A3.2.10 shows an interface between M17 board and OPE unit.
Figure A3.2.11 shows the related signals of PC1 and PC2.

2.

Function

1)

External status supervising interface (PC1/PC2)

External status is detected by the photocouplers (PC1/PC2) in the mechanism and the signal is

output to the input port of CPU via this interface circuit.

PC1: Presence of document on hopper.

When sub-power supply is applied to the fax machine, this signal is output to OPE unit
which will control the main-power supply.

PC2: Presense of document at scanning position.

3.

Others

NCU interface signal

CML

:

Line seizure control signal

DP

:

Dial pulse control signal

SR

:

Control signal for connection between LINE and TEL terminals

MUTE

:

Control signal for pulse dial improvement and bell shunt replay

PP

:

Relay control signal for special service code detection at parallel pickup or
remote reception

PBXE

:

Control signal for connecting one of LINE terminal to the PBXE terminal

OH2

:

Detection of off-hook of terminal connected to TEL-1 or TEL-2

OH1

:

Output upon circuit current detection after fax line seizure

RP

:

Receiving sensistivity determination terminal

RI

:

Ringing detection signal

S

:

Send signal (picture data/protocol/tonal signals/PB tone etc.)

R

:

Received signal (picture data/protocol/tonal signals etc.)

OPE interface signals

TXDOPE

:

This signal transmits sequencially the contents of each data of TXD (LED
on/off information, etc.) to OPE in serial data from CPU.

RXDOPE

:

This signal transmits sequencially the contents of each data of RXD (key
code information, etc.) to CPU in serial data from OPE.

OPECHK

:

Use to monitor the operation of the OPE unit.

OPERST

:

Reset signal for OPE unit

WAKEUP-N

:

Wakeup signal

PSMODE

:

Power Save Mode off signal from OPE.

MP/OFF

:

Main Power On/Off signal to Main Power Supply Unit.

MPREQ

:

Main Power off signal from CPU.