Oki B4100 User Manual
Page 310
Advertising
40055101TH Rev.4
310 /
No CB (+400V) output
voltage is provided.
No DB1/DB2 output
voltages are provided.
No
No
Is TR1 (+1KV) current
in the CC (Constant Current)
mode smaller or lager
than the specified value?
No
Yes
No current in the CC
mode flows.
See ACTION 13.
Yes
See ACTION 12.
2
See ACTION 11.
Yes
See ACTION 10.
Yes
See ACTION 10.
Yes
Is output voltage in the
CV (Current Voltage) mode
smaller or larger than
specified value or is not
provided?
See ACTION 14.
Yes
3
Is TR2 (-750V) output
voltage higher or smaller
than the specified value?
No
No
No