High voltages are activated by IOGA and generated by the high-voltage circuit inside the
power supply unit. The CH (charge) voltage of about -1.35kV is used for the charge roller.
The TR1/TR2 (transfer) voltage of about +3.5kV/-0.75kV is used for the transfer roller.

Medium voltages are activated by IOGA and generated by the medium-voltage circuit
inside the power supply unit. The SB1/SB2 (toner supply) voltage of about +0V/-450V is
used for the toner supply roller. The DB1/DB2 (developing) voltage of about +300V/-
300V is used for the developing roller. The CB (cleaning) voltage of about +400V is used
for the cleaning roller.

Figure A3.1.17 shows high/medium voltages control.

* Signals used to control the high/medium-voltages are listed below.

Signal Name

CHON

"1": CH is output.

Description

DBON1

"1": + ive polarity voltage of DB/SB is output.

DBON2

"1": - ive polarity voltage of DB/SB is output.

TRON1

"1": + ive polarity voltage of TR is output.

TRON2

"1": - ive polarity voltage of TR is output.

IOGA

DBON1
DBON2
DBPWM
TR1PWM
CHPWM
TR2PWM

R44

TLHV (OLHV)

High-voltage
generation
circuit

Medium-
voltage
generation
circuit

Contact assy.

Cleaning roller

Charge roller

EP drum

Transfer roller

Developing roller

Toner supply roller

CH

TR1/TR2

CB

DB1/DB2

SB1/SB2

Figure A3.2.17 High/Medium Voltages Control