Diagram 4-14-1

Configuration

This section explains configuration for the Software and for the VMware server.
Software Configuration
The VMware server works in console mode and can’t be used for configuration. Use a remote

Agent with the same Software version to configure the VMware server.

1. Start the manager interface on the remote software Agent in the Microsoft Windows operating

system.

2. If the two Agents are in the same LAN, the VMware server client will be added to the topology

automatically. Otherwise, add the Agent manually (select Monitor Remote Device from the Monitor
menu). The software will auto search the UPS when the Agent starts for the first time after
installation.

If the search fails:

▲ Select the VMware Server Agent from the tree view.

Acting as the Administrator, select Auto Search Device from the System menu. The UPS

connected with VMware server appears in the LAN tree view.

3. Select Shutdown Settings from the Device menu. Set the battery backup time, and select the

Begin Shutdown Immediately if Battery Low check box and the Run Command File before Shutdown
check box (refer to Diagram 4-14-2).

OK indicates that

VMware Tools are
available