3 Introduction

3.1 Introduction

3.1.1 About this Manual

First time users can obtain the most essential information for quick installation and set-up in these chapters:

Introduction

How to Install

How to Configure the System

For more detailed information including the full range of set-up options and diagnosis tools please refer to the chapters:

How to Control the AF-600 FP

How to Access AF-600 FP Parameters

Parameters

Troubleshooting

Echelon

®

, LonTalk

®

, Neuron

®

, LonWorks

®

and LonMaker

®

are registered trademarks of the Echelon Corporation.

3.1.2 Technical Overview

The LonWorks communications structure is similar to that of a local area network (LAN) in that messages are continually exchanged between a number of
processors. A LonWorks system is a local operating network (LON). LON technologyoffers a means for integrating various distributed systems that perform sensing,
monitoring, control, and other automated functions. A LON allows these intelligent devices to communicate with one another through a variety of communications
media using a standard protocol.

LON technology supports distributed, peer-to-peer communications. That is, individual network devices can communicate directly with one another without the
need for a central control system. A LON is designed to move sense and control messages which are typically very short and which contain commands and status
information that trigger actions. LONperformance is viewed in terms of transactions completed per second and response time. Control systems do not require
vast amounts of data, but they do demand that the messages they send and receive are absolutely correct.

Data are transported by means of standard network variable types (SNVTs) which provide a well- defined interface for communication between devices from
different manufacturers. Functional profiles defining the functionality and network variables for a particular family of devices (e.g. frequency converters, pumps
etc.) are also available, and supported by the LonWorks option.

3.1.3 Assumptions

These operating instructions assume, that the GE LonWorks option is used in conjunction with a GE AF-600 FPfan & pump drive. It is also assumed that the installed
controller supports the interfaces described in this document and that all the requirements stipulated in the controller, as well as the frequency converter, are