GE Industrial Solutions GPS2436 User Manual

Page 43

Advertising
background image

Galaxy Power System GPS2436

Issue 1 August 2012

43

Step

Action

NOTE:

The Remote Peripheral Monitoring feature has been designed into the

MCR1 board and requires no additional circuit packs. Monitoring and

control modules ARE required, based on the application.

NOTE:

This section only describes a single module connection to the controller.

Modules MUST BE PROGRAMMED after they have been installed or they

may not function properly. Detailed connection and configuration

information may be found in the User’s Guide for Millennium II Controller

Advanced Features manual.

1.

Using the RPM bus cable (comcode 407377704), wrap the cable through the

EMI inductor bead twice. Place the bead approximately 3 inches from the

end of the cable.

2.

Connect the bus cable to:

TB-1 Pin

Assignments

TB-1 Pin

Descriptions

RPM

Conductor

Color

RPM Conductor

Description

6

*6

Blue or White

Power/Communications

8

*8

Blue or White

Power/Communications

9 or 10

FGND

Bare wire

Shield

*connections of the bus wire are NOT polarity sensitive.

3.

Secure the module connection unit and route the wires through the open-

faced bottom of the connection unit.

4.

Make the connections to TB2 on the connection unit:

TB-2 Pin

Assignments

RPM

Conductor

Color

RPM Conductor

Description

IN

Blue or White

Power/Communications

OUT

Blue or White

Power/Communications

SHIELD

Bare wire

Shield

*connections of the bus wire are NOT polarity sensitive.
* there are 2 IN, and 2 OUT connections. Either one may be used.

5.

Locate the control unit. This is the half with circuitry on it.

6.

In the lower right hand side of the control unit (inside), are two rotary

switches. Set SW-1 (LO) to 1. The module will be recognized as 01 by the

controller. Other modules added cannot have the same address or 00 for

the address.

7.

Carefully attach the control unit to the connection unit using the ribbon

connector.

NOTE:

This connector/cable is not keyed, so be careful to line up the pins properly.

Advertising