Parameter Send

Use the Parameter Send to change any of the MLP-Drive's Control Parameters.

Table 3-51 Parameter Send - Host Transmission

Character #

1

2

3

4

5

6

7

8

9

10

11

12

DEV # DEV # MSG

PAR # PAR #

DATA DATA

DATA

DATA

DATA

DESC

STX

10s

1s

TYPE

10s

1s

1000s 100s

10s

1s

FORM

ETX

ASCII

STX

0-9

0-9

3

0-9

0-9

0-9

0-9

0-9

0-9

0-8

ETX

The following is a description of the Parameter Send-Host Transmission Characters.

Character 1 - STX:

This is the first character in the character string. None of the other characters will
be recognized without this character prefix. Always use the ASCII “STX” character;
it enables the MLP-Drive's receive buffer.

Characters 2, 3 - Device #:

These characters are the access address of the MLP-Drive. This number identifies
individual MLP-Drives on a mutltidrop system. The MLP-Drive will accept data only
if this number matches the MLP-Drive's address (CP-70), with the exception of a
“00” address. The “00” address is universally accepted by all of the MLP-Drives
that are on the RS485 Serial Communications Interface.

Character 4 - Message Type:

This character should always be “3”.