Direct mode, Direct mode -8 – CONTREX MLP-Drive User Manual

Page 46

Advertising
background image

3 - 8

Direct Mode

In the Direct mode of operation, the drive output from the MLP–Drive to the motor drive
can be set directly. Direct mode is an open-loop mode of operation. Scaling,
Acceleration/Deceleration, and closed loop compensation (PID) software are not
involved in the Direct mode. The Direct mode is used in conjunction with the Run and
Stop controls.

The Direct Setpoint (CP-06) is entered as a percentage of the MLP–Drive's drive
output. To enable or disable Direct mode, use the Direct Enable (CP-61).

The factory default Control Parameters for the Direct mode are found in Table 3-2. To
modify the default parameters, refer to Table 3-3.

Table 3-2 Default Direct Mode Control Parameters

CP

Parameter Name

Parameter Value

CP-06

Direct Setpoint

0

CP-61

Direct Enable

0

Table 3-3 Entering Direct Mode Control Parameters

CP

Parameter Name

Parameter Value

CP-06

Direct Setpoint

CP-61

Direct Enable

Enter the percentage of the calibrated
full scale drive output at which you
want your system to operate.

Enter “1” to enable the Direct Mode.
Enter “0” to disable the Direct Mode.