Acceleration/Deceleration

Acceleration/Deceleration (CP-16 and CP-17) control the rate of speed change in
response to setpoint changes. These parameters apply to both the Master and
Follower modes of operation.

The MLP–Drive comes factory pre-loaded with default Control Parameters for
Acceleration/Deceleration. Generally, these default settings are suitable for most
applications and do not require modification. The factory default Control Parameters for
Timing are found in Table 3-37. To modify these default parameters, refer to
Table 3-38.

Table 3-37 Default Master or Follower Acceleration/Deceleration Control

Parameters

CP

Parameter Name

Parameter Value

CP-16

Acceleration Time

5.0

CP-17

Deceleration Time

5.0

Table 3-38 Entering Master or Follower Acceleration/Deceleration Control

Parameters

CP

Parameter Name

Parameter Value

CP-16

Acceleration Time

CP-17

Deceleration Time

Enter the desired number of seconds to
decrease the motor speed from 2000 to 0
RPMs.

Enter the desired number of seconds to
increase the motor speed from 0 to 2000

RPMs.

After the Control Parameters for Acceleration/Deceleration have been entered, you can
enter the Control Parameters for Tuning either the Master or the Follower mode. The
tuning Control Parameters are identical for both the Master and the Follower modes of
operations. Tuning is discussed in the following section.