CONTREX MLP-Drive User Manual

Page 178

Advertising
background image

C - 12

MP-59 FREQUENCY OVER FLOW COUNTER

The Frequency Over Flow Counter (MP-59) is a counter that increments each time the frequency
input to the MLP–Drive causes an overflow. To reset the counter to “0”, press the Clear key.

CP-60

OPEN LOOP

If CP-60 is set to "1", then the J6 Pin 12 input acts as the Scroll Down input. If CP-60 is set to
"2", then this input is the Open/Closed Loop input.

CP-61

DIRECT ENABLE

In the Direct mode of operation, the drive output from the MLP–Drive that is connected to the
motor drive can be set directly. Direct mode is an open-loop mode of operation. Use Direct
Enable (CP-61) to either enable or disable the Direct mode.

Enter "1" to enable the Direct Mode.
Enter “0” to disable the Direct Mode.

Enabled

Code

CP-62

INVERSE SCALING

Use Inverse Scaling (CP-61) to select either the Standard or the Inverse setpoint scaling format.

Enter “2” for Inverse Scaling.
Enter "1" for Standard Scaling.

Inverse Scaling

Code