Follower mode - analog setpoint – CONTREX MLP-Drive User Manual

Page 72

Advertising
background image

3 - 34

Follower Mode - Analog Setpoint

The MLP-Drive can be scaled for Engineering Unit setpoint entry and Tach display
operation using the analog input for the setpoint. The following Control Parameters give
the MLP-Drive the necessary information for analog setpoint operation in the Follower
mode.

Analog Input Allocation (CP-84)

Setting CP-84, Analog Input Allocation, to a value of "6" or "7" allocates
the analog input to be used as Follower Setpoint 1 (CP-03) or Follower
Setpoint 2 (CP-04), respectively.

Follower Engineering Units (CP-21)

The actual value of the Follower Engineeing Units if the system were to
operate with an analog setpoint level of 10.0 volts when the lead and
feedback are at their maximum operating RPMs. This is the maximum
calibrated analog input level (refer to Installation/Setup: Calibration,
Analog Input Calibration).

Note: The analog input does not need to operate to 10.0 volts full scale to be
used for the setpoint replacement.

Max RPM Feedback (CP-34)

This is the maximum RPM of the feedback sensor shaft during system
operation.

PPR Feedback (CP-31)

The number of gear teeth or encoder lines on the follower feedback
sensor per revolution.

Max RPM Lead (CP-33)

This is the maximum RPM of the lead sensor shaft during system
operation.

PPR Lead (CP-30)

The number of gear teeth or encoder lines on the lead sensor per
revolution.