Jog -55 – CONTREX MLP-Drive User Manual

Page 93

Advertising
background image

3 - 55

Jog

Jog increases the RPMs at the acceleration rate that you specified in Acceleration Time
(CP-16) until the Jog Setpoint (CP-05) is achieved. When Jog is terminated, there is no
Deceleration Time (CP-17); the drive comes to an immediate stop. The factory default
Control Parameter for Jog is found in Table 3-47. To modify this default parameter,
refer to Table 3-48.

Table 3-47 Default Jog Control Parameters

CP

Parameter Name

Parameter Value

CP-05

Jog Setpoint

50

Table 3-48 Entering Jog Control Parameters

CP

Parameter Name

Parameter Value

CP-05

Jog Setpoint

Enter the RPM at which you want your
system to operate when it is in Jog.

For information on the Jog Logic Input, refer to

Logic Control: Logic Inputs, Jog

.