APPENDIX C: PARAMETER SUMMARY -

NUMERIC QUICK REFERENCE

CP-01

MASTER SETPOINT 1

The Engineering Units value that you want your system to operate at when Master Setpoint 1
(CP-01) is active. If the Master Setpoint is equal to the Master Engineering Units (CP-20) then
the system will run at its maximum RPMs, or Max RPM Feedback (CP-34). The factory default
Master Setpoint Control Parameters are set at “0”.

CP-02

MASTER SETPOINT 2

The Engineering Units value that you want your system to operate at when Master Setpoint 2
(CP-02) is active. If the Master Setpoint is equal to the Master Engineering Units (CP-20) then
the system will run at its maximum RPMs, or Max RPM Feedback (CP-34). The factory default
Master Setpoint Control Parameters are set at “0”.

CP-03

FOLLOWER SETPOINT 1

The Engineering Units value that you want your system to operate at when Follower Setpoint 1
(CP-03) is active. The Follower setpoint values are the ratio of Follower speed to Lead speed.

CP-04

FOLLOWER SETPOINT 2

The Engineering Units value that you want your system to operate at when Follower Setpoint 2
(CP-04) is active. The Follower setpoint values are the ratio of Follower speed to Lead speed.

CP-05

JOG SETPOINT

In Jog Setpoint (CP-05), enter the RPM at which you want your system to operate when it is in
Jog. Jog increases the RPMs at the acceleration rate that you specified in Acceleration Time
(CP-16) until the Jog Setpoint (CP-05) is achieved. When Jog is terminated, there is no
deceleration time; the drive comes to an immediate stop.