3 - 39

Offset Authority (CP-76)

Offset Authority determines the quantity of the offset term (amount of
influence) for a given analog input level.

Offset Polarity (CP-77)

Offset Polarity determines if the offset term is added or subtracted from
the follower scaled reference. If CP-77 is set to 1 (additive), analog
input voltages greater than CP-75 (Offset Null) will cause an increase in
follower speed. Analog input voltages less than Offset Null will cause a
reduction in follower speed.

If CP-77 is set to 2 (subtractive), analog input voltages greater than
Offset Null will cause a decrease in follower speed. Input voltages less
than Offset Null will cause an increase in speed.

Table 3-28 Default Scaling Control Parameters

CP

Parameter Name

Parameter Value

CP-84

Analog Input Allocation

0

CP-21

Follower Engineering Units

1.000

CP-34

Max RPM Feedback

2000

CP-31

PPR Feedback

60

CP-33

Max RPM Lead

2000

CP-30

PPR Lead

60

CP-75

Offset Null

000.0

CP-76

Offset Authority

100.0

CP-77

Offset Polarity

1