Feedback Frequency

(J5 pins 2, 3)

The Feedback Frequency is a pulse
train input that the MLP–Drive uses to
determine the speed of the follower
motor. For signal level specifications
refer to

References: Appendix A

,

MLP–Drive Specifications

.

Run

(J5 pins 4, 8)

When the Run input (J5 pin 4) is
momentarily shorted to common, the
MLP–Drive enters Run. As a
momentary input, Run is internally
latched and does not need to be
maintained by an operator device.

NOTE: Close the R–Stop and F–Stop

inputs prior to entering Run.
If you are only using one of
the Stop inputs, wire short the
other Stop input to common
or the MLP–Drive will not
enter “Run”.

Figure 2-7 Feedback Frequency

Figure 2-8 Run

Signal

Common

2

3

J5

RUN

4

8

J5

If the Feedback Frequency is lost,
the MLP-Drive will command a 100% Speed Out
and the motor will run at 100% capacity.
This can cause severe injury, death or
equipment damage.

DANGER