Follower Mode - Analog Feedback

The MLP-Drive can be scaled for Engineering Unit setpoint entry and Tach display
operation using the analog input for the feedback signal. The following Control
Parameters give the MLP-Drive the necessary information for analog feedback
operation in the Follower mode.

Analog Input Allocation (CP-84)

Setting CP-84, Analog Input Allocation, to a value of "2" allocates the
analog input to be used as the feedback source.

Follower Engineering Units (CP-21)

The actual value of the Follower Engineering Units if the system were to
operate with an analog feedback level of 10.0 volts and a lead of Max
RPM Lead (CP-33). This is the maximum calibrated analog input level
(refer to Installation/Setup: Calibration, Analog Input Calibration).

Note: The analog input does not need to operate to 10.0 volts full scale to be
used for analog feedback.

Max RPM Lead (CP-33)

This is the maximum RPM of the lead sensor shaft during system
operation.

PPR Lead (CP-30)

The number of gear teeth or encoder lines on the lead sensor per
revolution.

Table 3-22 Default Scaling Control Parameters

CP

Parameter Name

Parameter Value

CP-84

Analog Input Allocation

0

CP-21

Follower Engineering Units

1.000

CP-33

Max RPM Lead

2000

CP-30

PPR Lead

60