CONTREX MLP-Drive User Manual
Page 127
3 - 89
Characters 5,6 - Parameter Number:
The Control Parameter code is sent back to the host computer from the MLP-Drive.
Characters 7 through 10 - DATA:
The Control Parameter data that was requested is sent back to the host computer
from the MLP-Drive. For an interpretation of the MP-50 through MP-56, and CP-73
data, refer to Table 3-58. For the ASCII to binary conversion, refer to Table 3-57.
Character 11 - Data Format:
Character 11 indicates the decimal location and polarity of the data that was
transmitted in characters 7 through 10.
Use the following codes to indicate decimal location and polarity:
Code
Format
Code
Format
0
+XXXX
9
+XXX.X.
1
+XXX.X
:
+XX.XX.
2
+XX.XX
;
+X.XXX.
3
+X.XXX
4
-XXXX
5
-XXX.X
6
-XX.XX
7
-X.XXX
8
+XX.XX.
Codes “0” through “7” are valid for CP-20 and CP-21. All other Code Parameters
have either fixed or derived decimal locations and must use Code “0”. Code 8 is
valid for MP-41 amd MP-43. For codes 9, :, and ; multiply charactres 7 through 10
by ten.
Character 12 - ETX:
The return message is always terminated with the ASCII “ETX” character.