Characters 5,6 - Parameter Number:

The Control Parameter code is sent back to the host computer from the MLP-Drive.

Characters 7 through 10 - DATA:

The Control Parameter data that was requested is sent back to the host computer
from the MLP-Drive. For an interpretation of the MP-50 through MP-56, and CP-73
data, refer to Table 3-58. For the ASCII to binary conversion, refer to Table 3-57.

Character 11 - Data Format:

Character 11 indicates the decimal location and polarity of the data that was
transmitted in characters 7 through 10.
Use the following codes to indicate decimal location and polarity:

Code

Format

Code

Format

0

+XXXX

9

+XXX.X.

1

+XXX.X

:

+XX.XX.

2

+XX.XX

;

+X.XXX.

3

+X.XXX

4

-XXXX

5

-XXX.X

6

-XX.XX

7

-X.XXX

8

+XX.XX.

Codes “0” through “7” are valid for CP-20 and CP-21. All other Code Parameters
have either fixed or derived decimal locations and must use Code “0”. Code 8 is
valid for MP-41 amd MP-43. For codes 9, :, and ; multiply charactres 7 through 10
by ten.

Character 12 - ETX:

The return message is always terminated with the ASCII “ETX” character.