Teledyne LeCroy

Advanced Mode (User‐Defined)

116

 

 

Sierra M6‐2 SAS/SATA Protocol Analyzer User Manual

Figure 2.83: SAS: Choosing a Trigger Condition

2. Define each selected pattern in the same way as in Easy Mode, as described starting

on

page 66

. To use a timer, define it first.

Note:

You can set a timer for any If or Else If condition.

3. Enter a value for the number of occurrences before trigger in the Cont field, up to a

maximum of 65535 occurrences.

4. Choose a capture option: Everything, Nothing, or Pattern.
5. If you choose Pattern, you can select patterns for inclusion or exclusion. Clicking the

Pattern option enables a pattern definition dialog (see

Figure 2.84 on page 116

).

Figure 2.84: SAS: Choosing a Pattern

6. Choose pattern(s) and click the +>> button to add them for capture or exclusion. You

define each pattern the same way as in Easy mode (see

“Defining Patterns” on

page 66

).

7. For an output trigger, click the down arrow in the Ext. Out field and choose an

output trigger level. Note: Do not use the LOW setting in Advanced Mode.

8. To go to another state, click the down arrow in the Go To field and select a state. If

no other state has been defined, choose New State to add a state.