Teledyne LeCroy Sierra M6-2 SAS_SATA Protocol Analyzer User Manual User Manual

Page 435

Advertising
background image

    

Sierra M6‐2 SAS/SATA Protocol Analyzer User Manual

433

Sierra Trainer Generation Commands

Teledyne LeCroy

CONNECT

Generator will go through connection
sequence using current GenFile settings
(gen mode, speed, and so on). Generation
will not resume until connection is
established.

DISCONNECT

Generator will break existing connection to
DUT.

PAUSE

Generator will come to a break and the
user will be able to resume generation by
pressing Resume button on Generation
toolbar. Generator shall transmit idle

DWORD

s while in the Pause.

OUTPUT_ON

Takes the Trainer out of Electric Idle state. If
it is already out of Electric Idle, this is a
NOP.

OOB Commands
COMINIT

Generator will send COMINIT OOB signals
using current COMINIT settings.

COMRESET

Generator will send COMRESET OOB signals
using current COMRESET settings.

COMWAKE

Generator will send COMWAKE OOB signals
using current COMWAKE settings.

COMSAS

Generator will send COMSAS OOB signals
using current COMSAS settings.

SATA_ALIGN

Generator will go through SATA_ALIGN
stage of SATA SpeedNeg process using
current SATA_ALIGN settings.

SATA_D10_2

Generator will go through SATA_D10_2
stage of SATA SpeedNeg process using
current SATA_D10_2 settings.

SPEED_NEG_RCDT

Generator will go through
SPEED_NEG_RCDT stage of SAS SpeedNeg
process using current SPEED_NEG_RCDT
settings.

SPEED_NEG_ALIGN0

Generator will go through
SPEED_NEG_ALIGN0 stage of SAS
SpeedNeg process using current
SPEED_NEG_ALIGN0 settings.

SPEED_NEG_ALIGN1

Generator will go through
SPEED_NEG_ALIGN1 stage of SAS
SpeedNeg process using current
SPEED_NEG_ALIGN1 settings.

Advertising