Teledyne LeCroy Sierra M6-2 SAS_SATA Protocol Analyzer User Manual User Manual
Page 153
Sierra M6‐2 SAS/SATA Protocol Analyzer User Manual
151
Emulation
Teledyne LeCroy
Figure 2.141: SAS: Outgoing Frame Setting Dialog SCSI
Frame Type Error
Check this to introduce a frame type error.
Drop link for
Check this to drop link for the specified milliseconds.
Remove Frame from sequence
Check this to remove frame from sequence.
Delay in sending frame
Check this to delay sending frame and enter a value for the delay.
Frame Length Error
Check Frame Length Error, then choose the type of error to introduce.
Code violation and Disparity error
Check these and specify DWORD offset and the number of error DWORDs.
Don’t check credit
Check this to disable credit checking.
SOF, EOF and CRC errors
Check these and specify Double or Omit by checking the corresponding option button.
Insert Primitive
Check Insert Primitive, click the Type button to open the Primitive Type dialog, then
select the primitive type.