Teledyne LeCroy Sierra M6-2 SAS_SATA Protocol Analyzer User Manual User Manual

Page 148

Advertising
background image

Teledyne LeCroy

Emulation

146

 

 

Sierra M6‐2 SAS/SATA Protocol Analyzer User Manual

Insert Primitive

Check Insert Primitive and then click the Type button to open the Primitive Type dialog
and select the primitive type.

Figure 2.135: Primitive Type Dialog

Click the down arrow on the Primitive combo box, choose a primitive, then click OK.

Fill reserved fields with

Enter a value for which reserved fields to change, if other than 0.

Field of Frame

Select Destroy, scroll through the available choices in the Field of Frame list box, and
choose a field to destroy. Alternatively, select Specify Value to fill the chosen field with a
pre‐defined value.

Insert Frame

Check Insert Frame, click the down arrow on the Type combo box, and choose the frame
type.Then choose to insert it before or after an outgoing frame command. Make sure that
you have clicked More.

Note:

In addition to the pre‐defined frame types, you can scroll down the list to User Defined and

enter your own frame data between SOF and EOF.