Trainer Script Enhancements

430

 

 

Sierra M6‐2 SAS/SATA Protocol Analyzer User Manual

5.13.5

Using Variable Values in Creating Patterns on Bus

In creating patterns to send on bus, trainer script allows using variables. In these cases,
because the created pattern is dynamic, it is not possible to do scrambling and calculating
in software code. These tasks are done in the hardware engine. To activate, set “Auto
scramble mode” in “on” state.

The following examples show uses of variables in creating patterns.

Use variable for field value:

SendOpenAddressFrameSSP

{

InitiatorPort = 0x1

InitiatorConnectionTag = @variableName1

…...

}

The constraints are:

Field Length bigger than 64 bit is not supported.

Field StartBitOffset and EndBitOffset should be in same DWORD, except for
length bigger than 32.

Use LRF directly for field value:

SendSSPFrameCommand_Initiator

{

Data = LRF[startBitOffset:endBitOffset]

Tag = 0x101

}

The constraints are:

Length bigger than 64 bit is not supported.

Offsets (StartBitOffset and EndBitOffset) should be in same DWORD, except for
length bigger than 32.

SendSSPFrameCommand

{

#Data = {00112233 @variableName1 @variableName2 44556677}

}

RawData {

K28.5 D24.0 D30.0 D01.4

@variableName1

50 00 62 B0

00 00 00 30

50 08 05 EF

$C

00 00 00 01

00 00 00 00

SendCRC

K28.5 D24.0 D07.3 D31.4 }

}