Sierra M6‐2 SAS/SATA Protocol Analyzer User Manual

143

Emulation

Teledyne LeCroy

LBA Overlay - Overwrites first Dword of:

Check the LBA Overlay ‐ Overwrites first Dword of check box. Select one of the two
options:

Each sector with: Overwrites first Dword of each sector with given value

First sector with: Overwrites first Dword of first sector with given value band
increments for next sector(s)

Random Error Injection

Random Error Injection specifies the probability of Error Injection on the command. The
probability percentage that you select applies to all Error Injection items.

Close Connection Setting

Checking Close Connection Setting enables the Error Settings button. Click this button to
display the Close Connection Setting dialog.

Figure 2.131: Close Connection Dialog

Select the Close Sequence Type from the drop‐down list. Selecting Delay in sending
allows you to specify the delay in sending Done, Close, or Break.

Select the Close Connection Settings from the drop‐down lists.

Outgoing Open Error

Check Outgoing Open Error and then the enabled Error Settings button to display the
Open Frame Setting dialog.

Figure 2.132: Open Frame Setting Dialog

Check errors to introduce.