3. Connect the OUT Clock connector of Unit 1 to the IN Clock connector of Unit 2 using 

the supplied stacking cables. Similarly connect any additional units.

4. Connect the OUT 10‐pin connector of Unit 1 to the IN 10‐pin connector of Unit 2 

using the supplied stacking cables. Similarly connect any additional units.

Note:

Unit 1 must be the unit that has the first out connection.

Note:

The Self Test, SAS Verification Test, SATA Compliance Test and Update License functions only 

work on unit 1 when the analyzers are set up in cascading mode.

Figure 1.7: Cascading

Figure 1.8: Cascading Correctly

Correct way to connect:
The black color pin of the
ribbon wire is connected
the same way between
2 connectors.

Cascading works correctly
in this case.