Teledyne LeCroy Sierra M6-2 SAS_SATA Protocol Analyzer User Manual User Manual

Page 336

Advertising
background image

Teledyne LeCroy

Compliance Test (SATA)

334

 

 

Sierra M6‐2 SAS/SATA Protocol Analyzer User Manual

6. Select the Compliance Type as Host or Device.
7. Select the Device Type as ATA or ATAPI.
8. When testing SSD devices, select the SSD Drive checkbox, to ensure correct test

results.

9. To view failed test traces in the sample viewer, check the

Automatically load failed test traces into Sierra trace viewer check box.

10. To save the failed test traces only, check the Save only failed test traces check box.
11. Enter a path and file name for the Compliance Report file, or use the default file

name and path: 
C:\Program Files\LeCroy\SATA Protocol Suite\User\Compliance_Device1.rtf

12. Enter a path and file name for the Saved Traces, or use the default folder: 

C:\Program Files\LeCroy\SATA Protocol Suite\User\

13. After you select tests, click Start.
14. The test runs and, after a brief period, displays the result.

Figure 3.159: Compliance Test Result

15. To save the current compliance setup for later use, click the Save button to open the

Save As dialog. Assign a meaningful name to the setup and save it as a *.cst
compliance file.

16. To run a previously defined setup, click the Load button and choose a previously

defined setup to run.

Note:

When you are running Compliance Test, do not connect the analyzer to the Host if testing a

Device. Do not connect the analyzer to the Device if testing Host. Such improper connections
can impact compliance‐test result validity.

Advertising